class
Amazonite::CloudWatch::DescribeAlarmsInput
- Amazonite::CloudWatch::DescribeAlarmsInput
- Reference
- Object
Included Modules
- JSON::Serializable
Defined in:
cloudwatch/describe_alarms_input.crConstructors
- .new(pull : JSON::PullParser)
- .new(alarm_names : Array(String) | Nil = nil, alarm_name_prefix : String | Nil = nil, alarm_types : Array(AlarmType) | Nil = nil, children_of_alarm_name : String | Nil = nil, parents_of_alarm_name : String | Nil = nil, state_value : StateValue | Nil = nil, action_prefix : String | Nil = nil, max_records : Int32 | Nil = nil, next_token : String | Nil = nil)
Instance Method Summary
-
#==(other : self)
Returns
trueif this reference is the same as other. -
#action_prefix : String | Nil
Use this parameter to filter the results of the operation to only those alarms that use a certain alarm action.
-
#action_prefix=(action_prefix : String | Nil)
Use this parameter to filter the results of the operation to only those alarms that use a certain alarm action.
-
#alarm_name_prefix : String | Nil
An alarm name prefix.
-
#alarm_name_prefix=(alarm_name_prefix : String | Nil)
An alarm name prefix.
-
#alarm_names : Array(String) | Nil
The names of the alarms to retrieve information about.
-
#alarm_names=(alarm_names : Array(String) | Nil)
The names of the alarms to retrieve information about.
-
#alarm_types : Array(AlarmType) | Nil
Use this parameter to specify whether you want the operation to return metric alarms, composite alarms, or log alarms.
-
#alarm_types=(alarm_types : Array(AlarmType) | Nil)
Use this parameter to specify whether you want the operation to return metric alarms, composite alarms, or log alarms.
-
#children_of_alarm_name : String | Nil
If you use this parameter and specify the name of a composite alarm, the operation returns information about the "children" alarms of the alarm you specify.
-
#children_of_alarm_name=(children_of_alarm_name : String | Nil)
If you use this parameter and specify the name of a composite alarm, the operation returns information about the "children" alarms of the alarm you specify.
-
#hash(hasher)
See
Object#hash(hasher) -
#max_records : Int32 | Nil
The maximum number of alarm descriptions to retrieve.
-
#max_records=(max_records : Int32 | Nil)
The maximum number of alarm descriptions to retrieve.
-
#next_token : String | Nil
The token returned by a previous call to indicate that there is more data available.
-
#next_token=(next_token : String | Nil)
The token returned by a previous call to indicate that there is more data available.
-
#parents_of_alarm_name : String | Nil
If you use this parameter and specify the name of a metric or composite alarm, the operation returns information about the "parent" alarms of the alarm you specify.
-
#parents_of_alarm_name=(parents_of_alarm_name : String | Nil)
If you use this parameter and specify the name of a metric or composite alarm, the operation returns information about the "parent" alarms of the alarm you specify.
-
#state_value : StateValue | Nil
Specify this parameter to receive information only about alarms that are currently in the state that you specify.
-
#state_value=(state_value : StateValue | Nil)
Specify this parameter to receive information only about alarms that are currently in the state that you specify.
- #validate! : Nil
Constructor Detail
Instance Method Detail
Returns true if this reference is the same as other. Invokes same?.
Use this parameter to filter the results of the operation to only those alarms that use a certain alarm action. For example, you could specify the ARN of an SNS topic to find all alarms that send notifications to that topic.
Use this parameter to filter the results of the operation to only those alarms that use a certain alarm action. For example, you could specify the ARN of an SNS topic to find all alarms that send notifications to that topic.
An alarm name prefix. If you specify this parameter, you receive information about all alarms that have names that start with this prefix.
If this parameter is specified, you cannot specify AlarmNames.
An alarm name prefix. If you specify this parameter, you receive information about all alarms that have names that start with this prefix.
If this parameter is specified, you cannot specify AlarmNames.
The names of the alarms to retrieve information about.
Use this parameter to specify whether you want the operation to return metric alarms, composite alarms, or log alarms. If you omit this parameter, only metric alarms are returned, even if composite alarms or log alarms exist in the account.
For example, if you omit this parameter or specify MetricAlarms, the operation returns only a
list of metric alarms. It does not return any composite alarms or log alarms, even if they exist
in the account.
If you specify CompositeAlarms, the operation returns only a list of composite alarms, and
does not return any metric alarms or log alarms.
If you specify LogAlarms, the operation returns only a list of log alarms, and does not return
any metric alarms or composite alarms.
Use this parameter to specify whether you want the operation to return metric alarms, composite alarms, or log alarms. If you omit this parameter, only metric alarms are returned, even if composite alarms or log alarms exist in the account.
For example, if you omit this parameter or specify MetricAlarms, the operation returns only a
list of metric alarms. It does not return any composite alarms or log alarms, even if they exist
in the account.
If you specify CompositeAlarms, the operation returns only a list of composite alarms, and
does not return any metric alarms or log alarms.
If you specify LogAlarms, the operation returns only a list of log alarms, and does not return
any metric alarms or composite alarms.
If you use this parameter and specify the name of a composite alarm, the operation returns
information about the "children" alarms of the alarm you specify. These are the metric alarms
and composite alarms referenced in the AlarmRule field of the composite alarm that you specify
in ChildrenOfAlarmName. Information about the composite alarm that you name in
ChildrenOfAlarmName is not returned.
If you specify ChildrenOfAlarmName, you cannot specify any other parameters in the request
except for MaxRecords and NextToken. If you do so, you receive a validation error.
Only the Alarm Name, ARN, StateValue (OK/ALARM/INSUFFICIENT_DATA), and
StateUpdatedTimestamp information are returned by this operation when you use this parameter.
To get complete information about these alarms, perform another DescribeAlarms operation and
specify the parent alarm names in the AlarmNames parameter.
If you use this parameter and specify the name of a composite alarm, the operation returns
information about the "children" alarms of the alarm you specify. These are the metric alarms
and composite alarms referenced in the AlarmRule field of the composite alarm that you specify
in ChildrenOfAlarmName. Information about the composite alarm that you name in
ChildrenOfAlarmName is not returned.
If you specify ChildrenOfAlarmName, you cannot specify any other parameters in the request
except for MaxRecords and NextToken. If you do so, you receive a validation error.
Only the Alarm Name, ARN, StateValue (OK/ALARM/INSUFFICIENT_DATA), and
StateUpdatedTimestamp information are returned by this operation when you use this parameter.
To get complete information about these alarms, perform another DescribeAlarms operation and
specify the parent alarm names in the AlarmNames parameter.
The token returned by a previous call to indicate that there is more data available.
The token returned by a previous call to indicate that there is more data available.
If you use this parameter and specify the name of a metric or composite alarm, the operation
returns information about the "parent" alarms of the alarm you specify. These are the composite
alarms that have AlarmRule parameters that reference the alarm named in ParentsOfAlarmName.
Information about the alarm that you specify in ParentsOfAlarmName is not returned.
If you specify ParentsOfAlarmName, you cannot specify any other parameters in the request
except for MaxRecords and NextToken. If you do so, you receive a validation error.
Only the Alarm Name and ARN are returned by this operation when you use this parameter. To get
complete information about these alarms, perform another DescribeAlarms operation and specify
the parent alarm names in the AlarmNames parameter.
If you use this parameter and specify the name of a metric or composite alarm, the operation
returns information about the "parent" alarms of the alarm you specify. These are the composite
alarms that have AlarmRule parameters that reference the alarm named in ParentsOfAlarmName.
Information about the alarm that you specify in ParentsOfAlarmName is not returned.
If you specify ParentsOfAlarmName, you cannot specify any other parameters in the request
except for MaxRecords and NextToken. If you do so, you receive a validation error.
Only the Alarm Name and ARN are returned by this operation when you use this parameter. To get
complete information about these alarms, perform another DescribeAlarms operation and specify
the parent alarm names in the AlarmNames parameter.
Specify this parameter to receive information only about alarms that are currently in the state that you specify.
Specify this parameter to receive information only about alarms that are currently in the state that you specify.