trainhorn
Small, dependency-free Crystal calculators for train horn setups on trucks,
cars and boats. It is a port of the tested trainhorn_calc Python package
(and its Go port) and uses the same formulas and constants, so all of them
give the same numbers.
- Acoustics: SPL at a distance (inverse-square law, optional atmospheric absorption), the inverse (distance for a target level), loss per doubling of distance, and adding the levels of several horns.
- Air system: free air in a tank from Boyle's law, continuous horn runtime, whole blasts per tank, and compressor recovery time (constant or linear flow curve).
- Electrical: copper AWG diameter, area and resistance from the AWG definition, round-trip voltage drop, and the smallest gauge that meets a voltage-drop budget.
Every method validates its input and raises Trainhorn::InvalidInputError
(an ArgumentError) instead of returning a meaningless number.
Installation
Add the dependency to your shard.yml:
dependencies:
trainhorn:
github: train-horn/trainhorn-cr
version: ~> 1.0
Then run shards install.
Usage
require "trainhorn"
# A 150 dB horn rated at 10 ft, heard 100 ft away (free field).
Trainhorn.spl_at_distance(150.0, 100.0, 10.0) # => 130.0
# Same, in metres, with 1.9 dB/km air absorption (500 Hz band).
Trainhorn.spl_at_distance(150.0, 800.0, 10.0, "m", 1.9)
# Where does it fall to 90 dB?
Trainhorn.distance_for_spl(150.0, 90.0, 10.0) # => 10000.0 (ft)
Trainhorn.doubling_loss # => 6.020599913279624
Trainhorn.combine_levels(100.0, 100.0) # => 103.01029995663981
# 5 gal tank, 150 -> 110 psi, horn uses 10 CFM.
Trainhorn.tank_runtime_seconds(5.0, 150.0, 110.0, 10.0) # => 10.91566866267465
Trainhorn.blast_count(10.9, 2.0) # => 5
# Refill a 2 gal tank from 110 to 150 psi at 1.0 CFM.
Trainhorn.compressor_recovery_seconds(2.0, 110.0, 150.0, 1.0) # => 43.662674650698605
# 30 A compressor, 10 ft one-way run, 12 V, 3 % drop budget.
s = Trainhorn.suggest_awg(30.0, 10.0, 12.0, 3.0)
s.awg # => "6"
s.voltage_drop_pct # => 1.9753226951012177
Pressures are gauge psi. Lengths take a unit, "ft" (default) or "m".
Limits
These are engineering estimates from simple models (free field, isothermal
expansion, voltage drop only). They are not measurements and not a legal
noise assessment. suggest_awg does not check ampacity or fuse sizing;
always fuse to protect the wire you choose.